МULTIFREQUENCY PROTECTING METHOD AGAINST EARTH-FAULTS OF PHASE IN THE COMPENSATED ELECTRIC NETWORKS
DOI:
https://doi.org/10.20998/2074-272X.2020.1.09Keywords:
electrical network, earth fault protection, zero sequence current and voltage, Fourier transform, frequency spectrumAbstract
Introduction. A significant proportion of earth faults in 6 - 35 kV networks is a transient and short-lived process, which is followed by an electric arc. Problem. In such cases, earth-fault protection that responds to steady-state current and voltage is not able to operate properly. Also, the use of the Petersen coil to compensate for the capacitive earth fault current complicates the protection function because it significantly reduces the single phase earth fault current in steady state. Purpose. To develop selective single-phase earth faults protection algorithm using harmonic components that occur in zero-sequence currents and voltage in the transient process. Method. A mathematical model of the power supply system is applied to study the frequency components of currents and voltage of zero sequence in compensated electrical networks with phase-to-earth faults, and a mathematical model is used to test the operation of the developed protection algorithm. The results showed that, the reactive power for harmonic components of the frequency greater than 100 Hz, which are separated from the current and voltage of zero sequence in compensated electrical networks on the damaged feeder, is positive regardless of the degree of compensation of the capacitive current. That may be the basis of the principle of directional protection. Originality. Phase-to-earth fault selective protection algorithm has been developed. In that algorithm, first derivatives of currents and voltages of zero sequence are found, to reduce the influence of aperiodic components. And then, by using of the Fourier transform, a number of harmonic orthogonal components are extracted from them. Reactive power is calculated for each of frequency component and their total sum is found. If that sum excess of threshold, the relay will make a decision. The reliability of the developed protection algorithm is confirmed by the results of mathematical modeling and verification of the test sample at the laboratory stand and by means of field signals that were recorded by digital loggers at the substations.References
Shafiq M., KiitamI., Taklaja P., Kütt L., Kauhaniemi K., Palu I. Identification and location of PD defects in medium voltage underground power cables using high frequency current transformer. IEEE Access, 2019, vol.7, pp. 103608-103618. doi: 10.1109/ACCESS.2019.2930704.
Marciniak L. General earth fault protection for MV networks using wavelet decomposition and Bayesian criterion. E3S Web of Conferences, 2019, vol.84, p. 02007. doi: 10.1051/e3sconf/20198402007.
Habrych M. Comparative performance study of the Hall sensor based directional ground fault protection in MV mining network with ineffective earthing. Przegląd Elektrotechniczny, 2016, no.8, pp. 251-254. doi: 10.15199/48.2016.08.65.
Kavaskar S., Mohanty N.K. Detection of high impedance fault in distribution networks. Ain Shams Engineering Journal, 2019, vol.10, no.1, pp. 5-13. doi: 10.1016/j.asej.2018.04.006.
Torres V., Guardado J.L., Ruiz H.F., Maximov S. Modeling and detection of high impedance faults. International Journal of Electrical Power & Energy Systems, 2014, vol.61, pp. 163-172. doi: 10.1016/j.ijepes.2014.03.046.
Daqing Hou. Detection of high-impedance faults in power distribution systems. 2007 Power Systems Conference: Advanced Metering, Protection, Control, Communication, and Distributed Resources, Clemson, SC, 2007, pp. 85-95. doi: 10.1109/PSAMP.2007.4740902.
Marciniak L. Identyfikacja zwarć doziemnych wysokorezystancyjnych w sieciach średnich napięć. Przegląd Elektrotechniczny, 2015, no.8, pp. 185-189. (Pol). doi: 10.15199/48.2015.08.45.
Syvokobylenko V.F., Lysenko V.A. Mathematical modeling of new algorithms for single-phase earth faults protection in a compensated electrical network. Problemele Energeticii Regionale, 2019, no.1-2(41), pp. 1-11. doi: 10.5281/zenodo.3239135.
Syvokobylenko V.F., Lysenko V.A. Microprocessor selective protection from the phase to the earth fault in electric networks with Petersen coil in neutral. Technical Electrodynamics, 2019, no.2, pp. 54-62. (Rus). doi: 10.15407/techned2019.02.054.
Marciniak L. Określenie nastaw zabezpieczenia ziemnozwarciowego z falkowymi kryteriami działania. Przegląd Elektrotechniczny, 2014, no.6, pp. 261-264. (Pol). doi: 10.12915/pe.2014.06.52.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2020 V. F. Syvokobylenko, V. A. Lysenko
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Authors who publish with this journal agree to the following terms:
1. Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
2. Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
3. Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work.