INFLUENCE OF MANUFACTURING QUALITY OF LAMINATED CORE ON A TURBOGENERATOR EXPLOITATION TERM
DOI:
https://doi.org/10.20998/2074-272X.2016.4.04Keywords:
laminated core, flexural deformation, stator of turbogenerator, flexural stiffness, insulation coating, pressing, time of exploitationAbstract
The problem of calculating the flexural deformation of the laminated core of the stator turbogenerator is examined. The evaluation of the effect of gluing the core sheets on its bending stiffness based on the compliance of the insulating cover sheet of active steel. An impact of pressing effort on the relative movement of the package of sheets is determined. An effect of wear of the insulating layer between sheets of laminated core on its reliability is determined. Conclusions are drawn on how to determine the possibility of extending the life of turbogenerators on the basis of the data obtained.References
1. Shevchenko V.V. Methods of quantitative assessment of technical condition electrical equipment to determine the need for its rehabilitation or replacement. Collected materials of the Int. sci.-pract. conf. «Modern trends in the MRO. Diagnostics of equipment of mining and metallurgical and energy complexes (PBMCs)», 10-12 September 2015, pp. 39-42. (Rus).
2. Vasilev V.S., Johansen V.I. Experience and projects construction of deep modernization of powerful turbogenerators stator in the conditions of power. Electrical Appliances 2003: Abstracts of the conference. St. Petersburg, Electrosila, 2003. pp. 9-12. (Rus).
3. Shevchenko V.V., Minko A.N. Modernization of constructions domestic turbogenerators taking into account the requirements to maintain their competitiveness. Bulletin of NTU «KhPІ», 2014, no.38(1081), pp. 146-155. (Rus).
4. Warsawskiy G.Y. Influence segments and laminating the stator iron on the magnetic vibration of electrical machines AC. St. Petersburg: Collected Electrosila, 1989, no.37, pp. 42-45. (Rus).
5. Vaskovskyi Yu.N., Shumilov Yu.A., Shtogrin A.V. Analysis of vibration-exciting axial forces in a powerful turbo-generator stator core. Electrical engineering & electromechanics, 2009, no.2, pp. 21-26. (Rus). doi: 10.20998/2074-272x.2009.2.04.
6. Geller P.L., Burak A.M., Sinayuk S.L. Indicators of active stator turbogenerator packages strength steel, which are glued. Dynamics and strength of powerful turbo- and hydrogenerators. – Collected USRIE, 1987, pp. 9-14. (Rus).
7. Johansen V.I. The effect on the rigidity of the stator core turbogenerator pasting active steel. Leningrad: Collection «Methods for calculating the turbo- and hydrogenerators», 1975, no.95, p. 103. (Rus).
8. Johansen V.I., Storozhev V.D. Calculation of the mechanical characteristics of the bonded electrical steel packages. Leningrad: Collection Electrosila, 1976, no.31, pp. 102-105. (Rus).
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2016 V. V. Shevchenko

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Authors who publish with this journal agree to the following terms:
1. Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
2. Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
3. Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work.