CALCULATION OF COMPENSATING SUSCEPTANCE FOR A THREE-WIRE NET
DOI:
https://doi.org/10.20998/2074-272X.2014.1.13Keywords:
three-phase network, compensation, asymmetrical voltage, reactive powerAbstract
A problem of inactive power compensation in a three-wire three-phase network under asymmetrical sinusoidal voltage is considered. An algorithm for calculating susceptance of a Δ-compensator for the total current component active power of which equals zero is introduced. Examples of calculation are given.
References
Sirotin Yu.A. Jenergeticheskie rezhimy trehfaznoj trehprovodnoj cepi. Bulletin of NTU "KhPІ", 2013, no.17, pp. 129-143.
Sirotin Yu.A. Optymal'naya kompensatsyya pul'satsyy pry nesymmetrychnom napryazhenyy. Technical electrodynamics, 2013, no.3, pp. 73-80.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2015 Iu. A. Sirotin
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Authors who publish with this journal agree to the following terms:
1. Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
2. Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
3. Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work.